IoT & Smart Devices
Recommended ratings: IP54, IP65, IP67, IP68
Connected sensors and wearables for indoor and outdoor deployment. IP54 for indoor rugged, IP67 for outdoor portables.
Common use cases
- Outdoor environmental sensors
- Smart-home weather stations
- Wearable health monitors
- Asset-tracking tags
IP ratings used in iot & smart devices
12 ratings mapped to this industry.
IP65 is dust-tight and resists low-pressure water jets (6.3 mm nozzle, 30 kPa). It is the most common standard for fully exposed outdoor electronics such as lighting, cameras, and EV chargers.
IP67 is dust-tight and withstands temporary immersion in water up to 1 meter for 30 minutes. The go-to rating for outdoor and rugged devices that may be briefly submerged.
IP07 is an ingress protection code that ensures no protection against solid objects and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 0 with second-digit (liquid) level 7.
Built to withstand no protection against solid objects and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. Classified as IEC 60529 ingress protection code IP08, it pairs solid level 0 with liquid level 8.
Built to withstand protection against solid objects larger than 50 mm and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. Classified as IEC 60529 ingress protection code IP17, it pairs solid level 1 with liquid level 7.
The IP18 classification guarantees protection against solid objects larger than 50 mm and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 1 with second-digit (liquid) level 8.
The IP27 classification guarantees protection against solid objects larger than 12.5 mm and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 2 with second-digit (liquid) level 7.
Specified under IEC 60529, IP28 denotes protection against solid objects larger than 12.5 mm and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 2 with second-digit (liquid) level 8.
Specified under IEC 60529, IP37 denotes protection against solid objects larger than 2.5 mm and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 3 with second-digit (liquid) level 7.
IP38 provides protection against solid objects larger than 2.5 mm and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 3 with second-digit (liquid) level 8.
IP47 provides protection against solid objects larger than 1.0 mm and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 4 with second-digit (liquid) level 7.
Engineered to deliver protection against solid objects larger than 1.0 mm and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. Classified as IEC 60529 ingress protection code IP48, it pairs solid level 4 with liquid level 8.